Lindy U8 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Tastaturen Lindy U8 herunter. Lindy U8 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
4
OSD Configuration Menu
The OSD Menu displays further OSD configuration menus when selecting F1 from the main
OSD menu.
Select 01 LANGUAGE – for Supervisor only – to set the
OSD language to either: English, Francais, German,
Italiano, Espagnol, Japanese, Chinese or Russian.
Select 02 PORT NAME EDIT – for Supervisor only – to
change / assign names up to 10 characters long to the
computers attached to the appropriate ports.
Select 03 PORT SEARCH – all users – to search for any
computer name as assigned. If you type in only a few
characters all computers and ports will be displayed
containing these characters.
Select 04 USER SECURITY – for Supervisor only – to
assign the Supervisor password and users and their
passwords. For both up to 8 characters can be used
.
Select 05 ACCESS LIST – for Supervisor only – to assign access restrictions to users for
certain ports. Default setting is no access restriction. To disable a user from access to a certain
port go to the appropriate user and port and select the option by ENTER key. The sign in the
matrix list will change from 0 to X to indicate the access restriction.
Select 06 HOTKEY – for Supervisor only – to change the hotkey to any of the following: Scroll
Lock / Caps Lock / Left Ctrl / Right Ctrl / Left Alt / Right Alt / Left Win / Right Win. This hotkey
will permanently be changed.
Select 07 TIME SETTINGS – Supervisor only – set the Autoscan time from 5 up to 99 seconds.
Select 08 OSD MOUSE – for Supervisor only – to set the speed of the mouse movement in
OSD menu. There are 3 choices: slow, medium and fast. Use the appropriate setting for your
mouse.
Note: You can close the OSD window by simply pressing the ESCAPE key.
User and supervisor can only log out via the OSD menu when pressing F2 key
.
Please refer to the full User Manual on the supplied CD for more information about the
operation and advanced features of the U8/16 Modular KVM Switch
MAIN MENU
X
SELECT OPTION
01 LANGUAGE
02 PORT NAME EDIT
03 PORT SEARCH
04 USER SECURITY
05 ACCESS LIST
06 HOTKEY
07 TIME SETTINGS
08 OSD MOUSE
FCC Statement
Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a
suitably high level of immunity to electromagnetic
disturbances.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at their own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
LINDY KVM Switch U8/U16 Quick Start Guide
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (Nov 2007)
1
FOR COMMERCIAL USE ONLY! Tested to comply with FCC Standards
The LINDY Modular KVM Switch Series U8/U16
The U8/16 KVM switch series provides either 8 or 16 KVM server ports supporting both PS/2 and USB
keyboard and mouse connections. This KVM switch series incorporates a modular concept design which
allows for dual console access. The local console port allows direct access whilst a second console
option permits remote access either via remote IP or via a remote Cat.5 extender Unit. This allows
system administrators to access and administer their servers and KVM switches from a remote office
workstation. Optional KVM over IP or Cat.5 access modules may be purchased separately and are
simply installed into the back of a U8/16-Modular KVM Switch.
The U8/16 series KVM switches are compatible with almost any KVM switches using standard VGA,
keyboard and mouse signals. Please note however that compatibility is only provided via the server ports
of the U8/16 series KVM switch and not via the daisy chain ports! The U8/16 is also compatible with
older LINDY P-Series KVM switches. Should you wish to mix U- and P-series KVMs (or other brand
KVMs) then it has to be done via port cascading because daisy chain configuration of mixed U- and P-
series KVMs is not supported.
Package Contents
Cable Requirements
To connect each individual computer to the switch, you will need to purchase special LINDY
KVM system cables as listed below. If the connected computers are PS/2 only then you can use
the PS/2 version P16 and P-XT/-IP series system connection cables. To connect a USB
computer you have to use the additional PS/2 female to USB male adapter No. 70510.
U8/16, P16, P8/16XT, P16-IP KVM System cable with PS/2 Connectors
1m LINDY No. 32510
2m LINDY No. 32506
3m LINDY No. 32507
5m LINDY No. 32508
PS/2 to USB adapter LINDY No. 70510
Optional Cat.5 or KVM over IP Module Installation
If you wish to install the optional Cat.5 or KVM over IP module into the U8/16 Modular KVM switch
ensure all connected computers are switched off and the power supply is unplugged.
Power on Password
When you power on the U8/16 it will prompt you for a user name and a password. The default user
name and default password are both eight zeros –“00000000.
The security feature for the KVM Switch U8/U16 allows one Supervisor plus 8 users with individual
access rights. The configuration is made via the OSD menu – see below.
KVM Switch U8/U16
Power adapter
19”
Rack
mount kit
Daisy Chain Cable
Software & user manual CD
This quick start guide
This Quick Guide provides a brief introduction to the LINDY U8/16 Modular KVM
switch series and shows you how to quickly set up the device for use. For detailed
operating instructions please refer to the user manual supplied on the enclosed CD
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1

4 OSD Configuration Menu The OSD Menu displays further OSD configuration menus when selecting F1 from the main OSD menu. Select 01 LANGUAGE – for

Seite 2

2 + + + + + + + + + + + + Computer / Port Switching You can select the computer you want to access in three different ways  Front panel pus

Kommentare zu diesen Handbüchern

Keine Kommentare